Product number | HLC102535 |
---|---|
Cell model | 102535/3.7V/800mAh |
Battery specification | 102535-1S1P/3.7V/800mAh |
Nominal voltage | 3.7V |
Nominal capacity | 800mAh |
Charging voltage | 4.2V |
Charging current | ≤800mA |
Discharging current | ≤800mA |
End-off voltage | 3V |
Charging temperature | 0~45℃ |
Discharging temperature | -20~60℃ |
Weight | 14g |
Size | 10*25*35mm |
Application field | Smart Watch |
It is a 102535-800mAh minimal capacity. 0.2C5A standard discharge to 3.0V after 0.2C5A standard charge to 4.2V. Its energy density 415Wh/L.
Standard Charge(25±2℃): Constant current 0.2 C5A to 4.2V
Constant voltage 4.2V 0.02 C5A cut-off
Standard Discharge (25±2℃): Constant current 0.2 C5A 3.0V Cut-off
Max discharge current: 1.0 C5A
Operating temperature: Charging: 0°C ~ 9°C 0.2 C5A /4.2V,0.02 C5A cut-off
10°C~44°C 1.0 C5A /4.2V,0.02 C5A cut-off
45°C~50°C 0.5 C5A /4.2V,0.02 C5A cut-off
Discharge: -20°C ~ 60°C 1.0 C5A /3.0V
Storage (At 50% SOC and specified temp, recoverable capacity in % vs time.): 20±5℃ is the recommended storage temperature
-20℃~25℃, (12 months, ≥85%)
-20℃ ~35℃, (3 months, ≥85%)
-20℃ ~45℃, (1 month, ≥90%)
-20℃~60℃, (1 month, ≥80%)
Minimal Capacity:
Testing Instruction: The discharge performance means the time which is measured with discharge current of 0.2C CC(constant current) with 3.0V cut-off voltage within 1 hour after full charge.
Requirements: ≥800mAh
Cycle Life:
Testing Instructions: ≥500 cycles, more than 80% at std charge/std discharge(25±2℃)≥500, 80% thickness expansion ratio≤8%.
Requirements: nominal capacity 800mAh
Storage characteristics:
Testing instruction: After the standard charge, store in 25℃ for 30 days after full charge; After the standard charge, store in 60℃ for 7 days after full charge.
Requirements: retention capacity rate 85%, restoration capacity rate 90%.
Temperature characteristics:
Testing instruction: After the standard charge, a cell is stored in an environment of specific temperature for 2 hours, and then discharged to cut-off voltage 3.0V with a constant current of 0.2 C5A.
Requirements: Capacity rate at -10℃≥60%; at 0℃≥×70%; at 45℃ ≥ 100%;
Testing instruction: 25 ℃ environment, constant current constant voltage charging 0.2 C5A to 3.92±0.1V cut-off current 0.02C5A,,the high temperature45℃ for 72h. The normal temperature 25℃ for 96h.
Requirements: Voltage drop 10mV or less
We will contact you within 1 working day, please pay attention to the email with the suffix “@hlcbattery.com”.